BYHBF - INDIVIDUAL CHEMICAL AGENT DETECTOR, G SIMULANT COMPONENT

Product Identification

Product ID:INDIVIDUAL CHEMICAL AGENT DETECTOR, G SIMULANT COMPONENT
MSDS Date:07/14/1993
FSC:6665
NIIN:01-340-1693
Kit Part:Y
MSDS Number: BYHBF

Responsible Party
ENVIRONMENTAL TECHNOLOGIES GROUP INC
1400 TAYLOR AVE
BALTIMORE, MD 21284-9840
US

Emergency Phone: 410-321-5100 OR 410-321-5105

Info Phone: 410-321-5100 OR 410-321-5105

Cage: 23667

Contractor
ENVIRONMENTAL TECHNOLOGIES GROUP INC
9840 BALTIMORE, MD 21284-9840 US

Telephone: 301-321-5200

Cage: 23667

Ingredients

ACETIC ANHYDRIDE (CERCLA)

CAS: 108-24-7

RTECS: AK1925000

OSHA PEL 5 PPM

ACGIH TLV: 5 PPM; 9495

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


METHYL ISOBUTYL KETONE (HEXONE) (SARA 313) (CERCLA)

CAS: 108-10-1

RTECS: SA9275000

OSHA PEL 100 PPM

ACGIH TLV: 50 PPM/75 STEL; 9495

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS

Hazards

LD50 LC50 Mixture:PRODUCT'S LD50 (ORAL RAT) WAS NOT STATED
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:*RELEASE OF CHEMICALS, ICAD ACTIVATION
& SENSOR MODULE RUPTURE* ACUTE-EYE, SKIN ABSORPTION, INTOXICATION
EFFECT. CHRONIC-NOT APPLICABLE DUE TO VOLUME. *NORMAL ICAD
OPERATIONS* NO HEALTH EFFECTS, ACUT E OR CHRONIC.
Explanation of Carcinogenicity:MANUFACTURER GAVE NO INFORMATION ABOUT
CARCINOGENICITY. HMIS FOUND NO LISTING & DOES NOT EXPECT IT TO BE
CARCINOGENIC.
Effects of Overexposure:*RELEASE OF CHEMICALS, ICAD ACTIVATION & SENSOR
MODULE RUPTURE* INTOXICATION EFFECT, EYE & MUCOUS MEMBRANE
IRRITATION, BLURRED VISION. *NORMAL ICAD OPERATIONS* NO SYMPTOMS.
Medical Cond Aggravated by Exposure:*RELEASE OF CHEMICALS, ICAD
ACTIVATION & SENSOR MODULE RUPTURE* COPD (ASTHMA, EMPHYSEMA, TB,
BRONCHITIS). *NORMAL ICAD OPERATIONS* NONE.

First Aid

First Aid:EYE:WASH W/RUNNING WATER FOR MINIMUM OF 30 MIN. & SEEK
MEDICAL ATTENTION. SKIN:WASH W/RUNNING WATER FOR A MINIMUM OF 30
MIN. INHALATION:MOVE TO VENTILATED AREA (AWAY FROM SOURCE OF
EXPOSURE) - START O XYGEN THERAPY (IF NEEDED). INGESTION:DILUTE
W/LARGE QUANTITIES OF NEUTRALIZING SOLUTIONS (WATER, MILK).

Fire Fighting

Flash Point:80.6F,27.0C
Extinguishing Media:CARBON DIOXIDE, WATER, DRY CHEMICAL, POLYMER FOAM
Fire Fighting Procedures:MFR GAVE NO INFORMATION ON MSDS.
Unusual Fire/Explosion Hazard:MFR GAVE NO INFORMATION ON MSDS.

Accidental Release

Spill Release Procedures:MFR GAVE NO INFORMATION ON MSDS.
Neutralizing Agent:MFR GAVE NO INFORMATION ON MSDS.

Handling

Handling and Storage Precautions:STORE MATERIALS IN TEMPERATE WAREHOUSE
ENVIRONMENT TO ENSURE PRODUCT INTEGRITY - MAINTAIN FEDERAL
VENTILATORY STANDARDS FOR WAREHOUSE CONDITIONS.
Other Precautions:INITIAL ACTIVATION OF ICAD SHOULD BE PERFORMED IN AN
OPENLY VENTILATED ENVIRONMENT TO ENSURE PERSONNEL SAFETY. (USE
I/A/W ICAD USER MANUAL.)

Exposure Controls

Respiratory Protection:NONE REQUIRED (USE I/A/W ICAD USER MANUAL.)
Ventilation:MFR GAVE NO INFORMATION ON MSDS.
Protective Gloves:NONE REQUIRED,USE I/A/W ICAD USER MANUAL
Eye Protection:NONE REQUIRED,USE I/A/W ICAD USER MANUAL
Other Protective Equipment:MFR GAVE NO INFORMATION ON MSDS.
Work Hygienic Practices:MFR GAVE NO INFORMATION ON MSDS.
Supplemental Safety and Health
NONE

Chemical Properties

HCC:F6
NRC/State Lic Num:NONE
Boiling Pt:B.P. Text:262F,128C
Spec Gravity:0.87
Evaporation Rate & Reference:N/A (CARBON TET = 1)
Solubility in Water:INSOLUBLE
Appearance and Odor:COLORLESS LIQUID, FOUL STENCH

Stability

Stability Indicator/Materials to Avoid:YES
MFR GAVE NO INFORMATION ON MSDS.
Stability Condition to Avoid:STRONG OXIDIZING & REDUCING AGENTS
Hazardous Decomposition Products:MFR GAVE NO INFORMATION ON MSDS.
Conditions to Avoid Polymerization:MFR GAVE NO INFORMATION ON MSDS.

Disposal

Waste Disposal Methods:DISPOSE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS. (REFER TO 40CFR FOR GUIDANCE.)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.